Window and Door Profile has been widely used in home decoration. How to judge the quality of plastic steel doors and windows has become a topic of concern to consumers. There are many types of plastic steel doors and windows on the market, and non-professionals cannot judge the difference in quality from the appearance of Window and Door Profile. How to judge the production quality standards of plastic steel doors and windows?
1. The surface of the Window and Door Profile should be flat, the color should be basically uniform, no cracks, no bubbles, welding and cleaning should be neat, there should be no defects such as scars and impurities that affect the use, and the average angle.
2. The outdoor window should have a 25mm long drainage channel. The notch should be straight and should not penetrate into the bottom of the profile to ensure that the water invaded into the frame is discharged out of the room in time to prevent dust.
3. The allowable deviation of the width and height of window sashes, doors and windows below 2 meters should not be greater than +3mm, doors and windows above 2 meters should not be greater than +3.5mm
4. The difference of the diagonal size of the window frame and sash, the allowable deviation (300㎜~900㎜)≤+2.0㎜, (901㎜~1500㎜)≤+2.5㎜, (1501㎜~2000㎜)≤+3.0㎜
5. The assembly gap between two adjacent components is less than 0.5mm, and the flatness of the welding place of two adjacent components should not be greater than 0.8mm
6. The gap between the bottom corners of the glass beads is not more than 1mm, and the assembly is firm. Two beads should not be used on one side.
7. The hardware fittings are installed in the correct position, the quantity is complete, the installation is firm, the switch is flexible, and it is strong enough.
8. After the sealing strip is assembled, it should be uniform, firm, tightly connected, and there should be no grooves.
9. After the frame fan is assembled, the switch function must not be hindered, and the door and window sash must not be warped.
10. For the fixing of each section steel, there are no less than 3 screws, the spacing is not more than 300mm, and the distance from the end of the section steel is not more than 100mm. The fixed section steel must not be loosened.
11. The size of the glass is calculated from the light-transmitting side of the window frame and window sash, and the overlap of each side is not less than 8mm. When installing the glass, a shock-proof pad must be installed around the glass.
The above is the relevant content of Window and Door Profile. I hope it will help everyone. If you have any other questions, please consult online~